Series 35XHT
The pressure transmitters of the 35XHT series are suitable for use in media temperatures up to 150 °C and can therefore be used in bioreactors and autoclaves that have to be sterilised regularly. They use digital compensation with a mathematical model to achieve an accuracy of 0,15 %FS. In addition to the digital RS485 interface, the X-line transmitters have a rangeable, analog current or voltage output. The standard model of the 35XHT series has an Ingold fitting as pressure connection.
Pressure Ranges: | 0…1 to 0…30 bar |
Accuracy: | ± 0,05 %FS |
Total Error Band: | ± 0,15 %FS @ 20…120 °C |
Interfaces: | RS485, 4…20 mA, 0…10 V |
Temperature Range: | -20…150 °C |